Komatsu D155AX-6 — FAILURE CODE [DB90KT] WE CONTROLLER: ABNORMALITY IN CONTROLLER

40 Troubleshooting SEN00719-01 Troubleshooting by failure and error codes, Part 4 1 Failure code [DB90KT] WE controller: Abnormality in controller 1 D155AX-6 3 Action code Failure code Trouble WE controller: Abnormality in controller (Work equipment controller system) E01 DB90KT Contents of trouble • Information in ROM (non-volatile memory) of work equipment controller is abnormal. Action of controller • Sets internal adjustment values to default values. Problem that appears on machine • Operating feel of work equipment may become bad. • Adjusting function of machine monitor may not operate normally. Related information • Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective adjustment of work equipment controller Turn Adjustment function in service mode ON and perform opera- tion of reproducing trouble. If "E" of failure code disappears at this time, system is normal. • Adjustment code: 0031 (Initialization of work equipment controller) 2 Defective work equipment controller Troubleshooting cannot be carried out since defect is in work equipment controller. (If there is not any visible trouble in machine, controller may be used as it is.)