SEN00719-01 40 Troubleshooting Failure code [DBE0KT] PT controller: Abnormality in controller 1 14 D155AX-6 Action code Failure code Trouble PT controller: Abnormality in controller (Power train controller system) E01 DBE0KT Contents of trouble • Information in ROM (non-volatile memory) of power train controller is abnormal. Action of controller • Sets internal adjustment values to default values. Problem that appears on machine • Shifting feel of transmission may become bad. • Adjusting function may not operate normally. Related information • Method of reproducing failure code: Turn starting switch ON.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective adjustment of power train controller Turn Adjustment function in service mode ON and perform opera- tion of reproducing trouble. If "E" of failure code disappears at this time, system is normal. • Adjustment code: 0002 (Initialization of power train controller) 2 Defective power train con- troller Troubleshooting cannot be carried out since defect is in power train controller. (If there is not any visible trouble in machine, controller may be used as it is.)