SEN00719-01 40 Troubleshooting Failure code [DBE6KK] PT controller: Source voltage reduction 1 16 D155AX-6 Action code Failure code Trouble PT controller: Source voltage reduction (Power train controller system) E02 DBE6KK Contents of trouble • Voltage of 24V power supply circuit for power train controller sensors is below 17 V or above 30 V. • Abnormal current flowed in 24V power supply circuit for power train controller sensors. Action of controller • Turns output of 24V power supply circuit OFF, if abnormal current flows. • Limits operation of engine and transmission. Problem that appears on machine • System may not operate normally.
• Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. Related information • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective pitch angle sensor or torque converter pressure sensor (Internal trouble) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Disconnect devices at right in order. If "E" of failure code disappears when a device is discon- nected, that device has trouble in it.
Pitch angle sensor Connector PT1 Torque converter inlet pressure sensor Connector TIP Torque converter out- let pressure sensor Connector TOP 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC1 (female) (16) – PT1 (female) (C) [Pitch angle sensor sys- tem] Resis- tance Min. 1 Mz Wiring harness between STC1 (female) (16) – PIT (female) (B) [Torque converter inlet pressure sensor system] Resis- tance Min. 1 Mz Wiring harness between STC1 (female) (16) – TOP (female) (B) [Torque converter outlet pressure sensor system] Resis- tance Min.
1 Mz 3 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC1 Voltage Between (16) – (21) 20 – 30 V