SEN00719-01 40 Troubleshooting Failure code [DDDDKX] Back up brake Sw: Signal mismatch 1 38 D155AX-6 Action code Failure code Trouble Back up brake Sw: Signal mismatch (Power train controller system) E02 DDDDKX Contents of trouble • Brake pedal potentiometer signal does not match to brake pedal switch signal. Action of controller • None in particular. Problem that appears on machine • Backup brake may not operate. Related information • State of brake pedal potentiometer signal can be checked with monitoring function. (Code: 50400 Brake Pedal Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate brake pedal.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective brake pedal switch system If failure code [DDDDKA] or [DDDDKB] is also displayed, carry out troubleshooting for it first. 2 Defective brake pedal switch Adjust brake pedal and perform operation of reproducing trouble. If "E" of failure code disappears at this time, system is normal. • Testing and adjusting item: Adjusting brake pedal 3 Defective power train con- troller If causes 1 – 2 are not detected, power train controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)