Komatsu D155AX-6 — FAILURE CODE [DFA4KZ] BL LEVER: DISCONNECTION OR SHORT CIRCUIT

40 Troubleshooting SEN00720-01 Troubleshooting by failure and error codes, Part 5 1 Failure code [DFA4KX] BL lever 1: Out of normal range 1 Failure code [DFA4KZ] BL lever: Disconnection or short circuit 1 D155AX-6 3 Action code Failure code Trouble BL lever 1: Out of normal range (Work equipment controller system) E03 DFA4KX Contents of trouble • In blade control lever lift potentiometer 1 and 2 systems, either of failure codes [DFA5KA] and [DFA5KB] and either of failure codes [DFA6KA] and [DFA6KB] occurred simultaneously. Action of controller • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half).

• Once machine is stopped, travel is limited to F1 and R1. Related information • State of blade control lever lift potentiometer signal can be checked with monitoring function. (Code: 73400 Blade Lift Lever A Potentio) (Code: 73401 Blade Lift Lever B Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate blade control lever (in lifting direction). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Carry out troubleshooting for failure codes [DFA5KA], [DFA5KB], [DFA6KA], and [DFA6KB]. Action code Failure code Trouble BL lever:

Disconnection or short circuit (Work equipment controller system) E03 DFA4KZ Contents of trouble • In blade control lever lift potentiometer 1 and 2 systems, when starting switch is turned ON, only either side is abnormal and then either of failure codes [DFA5KA] and [DFA5KB] and either of fail- ure codes [DFA6KA] and [DFA6KB] occurred simultaneously. Action of controller • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. Related information • State of blade control lever lift potentiometer signal can be checked with monitoring function.

(Code: 73400 Blade Lift Lever A Potentio) (Code: 73401 Blade Lift Lever B Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate blade control lever (in lifting direction). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Carry out troubleshooting for failure codes [DFA5KA], [DFA5KB], [DFA6KA], and [DFA6KB].