Komatsu D155AX-6 — FAILURE CODE [DFA4L8] BL LEVER: SIGNAL MISMATCH

SEN00720-01 40 Troubleshooting Failure code [DFA4L8] BL lever: Signal mismatch 1 4 D155AX-6 Action code Failure code Trouble BL lever: Signal mismatch (Work equipment controller system) E03 DFA4L8 Contents of trouble • In blade control lever lift potentiometer 1 and 2 systems, total of both signal voltages is below 4.41 V or above 5.59 V. Action of controller • Continues control with signal of normal one of blade control lever lift potentiometer 1 and 2 systems. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1.

Related information • State of blade control lever lift potentiometer signal can be checked with monitoring function. (Code: 73400 Blade Lift Lever A Potentio) (Code: 73401 Blade Lift Lever B Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate blade control lever (in lifting direction). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Carry out troubleshooting for failure codes [DFA5KA], [DFA5KB], [DFA6KA], and [DFA6KB].