SEN00720-01 40 Troubleshooting Failure code [DFA7KX] BT lever 1: Out of normal range 1 Failure code [DFA7KZ] BT lever: Disconnection or short circuit 1 14 D155AX-6 Action code Failure code Trouble BT lever 1: Out of normal range (Work equipment controller system) E03 DFA7KX Contents of trouble • In blade control lever tilt potentiometer 1 and 2 systems, either of failure codes [DFA8KA] and [DFA8KB] and either of failure codes [DFA9KA] and [DFA9KB] occurred simultaneously. Action of controller • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half).
• Once machine is stopped, travel is limited to F1 and R1. Related information • State of blade control lever tilt potentiometer signal can be checked with monitoring function. (Code: 73500 Blade Tilt Lever A Potentio) (Code: 73501 Blade Tilt Lever B Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate blade control lever (in tilting direction). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Carry out troubleshooting for failure codes [DFA8KA], [DFA8KB], [DFA9KA], and [DFA9KB]. Action code Failure code Trouble BT lever:
Disconnection or short circuit (Work equipment controller system) E03 DFA7KZ Contents of trouble • In blade control lever tilt potentiometer 1 and 2 systems, when starting switch is turned ON, only either side is abnormal and then either of failure codes [DFA8KA] and [DFA8KB] and either of fail- ure codes [DFA9KA] and [DFA9KB] occurred simultaneously. Action of controller • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. Related information • State of blade control lever tilt potentiometer signal can be checked with monitoring function.
(Code: 73500 Blade Tilt Lever A Potentio) (Code: 73501 Blade Tilt Lever B Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate blade control lever (in tilting direction). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Carry out troubleshooting for failure codes [DFA8KA], [DFA8KB], [DFA9KA], and [DFA9KB].