Komatsu D155AX-6 — FAILURE CODE [DFAAL8] RL LEVER: SIGNAL MISMATCH

40 Troubleshooting SEN00720-01 Failure code [DFAAL8] RL lever: Signal mismatch 1 D155AX-6 25 Action code Failure code Trouble RL lever: Signal mismatch (Work equipment controller system) E03 DFAAL8 Contents of trouble • In ripper control lever lift potentiometer 1 and 2 systems, total of both signal voltages is below 4.41 V or above 5.59 V. Action of controller • Continues control with signal of normal one of ripper control lever lift potentiometer 1 and 2 sys- tems. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1.

Related information • State of ripper control lever lift potentiometer signal can be checked with monitoring function. (Code: 73700 Ripper Lift Lever A Potentio) (Code: 73701 Ripper Lift Lever B Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate ripper control lever (in lifting direction). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Carry out troubleshooting for failure codes [DFABKA], [DFABKB], [DFACKA], and [DFACKB].