SEN00720-01 40 Troubleshooting Failure code [DFABKA] RL lever 1: Disconnection 1 26 D155AX-6 Action code Failure code Trouble RL lever 1: Disconnection (Work equipment controller system) E03 DFABKA Contents of trouble • Signal voltage of ripper control lever lift potentiometer 1 system is below 0.5 V. Action of controller • Continues control with signal of ripper control lever lift potentiometer 2 system. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1.
Related information • State of ripper control lever lift potentiometer 1 signal can be checked with monitoring function. (Code: 73700 Ripper Lift Lever A Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate ripper control lever (in lifting direction). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor 5V power supply system If failure code [DB97KK] is also displayed, carry out troubleshoot- ing for it first.
2 Defective ripper control lever lift potentiometer 1 (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WLV2 (male) Ripper control lever Resistance Between (8) – (5) Neutral 3.2 kz ± 20 % Between (8) – (7) 1.6 kz ± 20 % Between (7) – (5) 1.6 kz ± 20 % 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC1 (female) (22) – WLV2 (female) (8) Resis- tance Max. 1 z Wiring harness between WEC1 (female) (14) – WLV2 (female) (7) Resis- tance Max.
1 z 4 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC1 (female) (14) – WLV2 (female) (7) and chassis ground Resis- tance Min. 1 Mz 5 Defective work equipment controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. WEC1 Voltage Between (14) – (21) 0.5 – 4.5 V