Komatsu D155AX-6 — COOLING FAN MOTOR

10 Structure, function and maintenance standard SEN00603-00 2. Suction valve Function q If the fan pump stops, the pressurized oil does not flow into the motor. Since the motor contin- ues revolution because of the force of inertia, however, the pressure on the outlet side of the motor rises. 2) When the pump is stopped q If the engine is stopped and the input revolu- tion of the fan pump lowers to 0 rpm, the pres- surized oil from the pump is not supplied to port (P) any more. As the pressurized oil is not supplied to the (MA) side of the motor, the motor speed lowers gradually to stop.

q When the oil stops flowing in from inlet port (P), suction valve (1) sucks in the oil on the outlet side and supplies it to port (MA) where there is not sufficient oil to prevent cavitation. q If the motor shaft is revolved by the force of inertia while the oil flow in the port (P) is reduc- ing, the oil in port (T) on the outlet side is sent by the suction valve (1) to the (MA) side to pre- vent cavitation. Operation q If the pressurized oil from the pump is supplied to port (P) and the pressure on (MA) side rises and starting torque is generated in the motor, the motor starts revolution.The pressurized oil on the motor outlet (MB) side of the motor returns through port (T) to the tank.

1) When pump is started D155AX-6 17