Komatsu D155AX-6 — COOLING FAN MOTOR

SEN00603-00 10 Structure, function and maintenance standard 3. Operation of reversible valve 1) When the ON-OFF solenoid is de-energized. q If ON-OFF solenoid (1) is “de-energized“, the pressurized oil from the pump is blocked by ON-OFF selector valve (2), and port (C) opens for the tank circuit. 2) When the ON-OFF solenoid is energized. q If ON-OFF solenoid (1) is “energized“, ON- OFF selector valve (2) changes to let the pres- surized oil from the pump flow through port (C) into spool chamber (D). q Spool (3) is pushed to the right by spring (4). q Motor port (MA) opens and pressurized oil flows in to revolve the motor in forward (clock- wise).

q The pressurized oil in chamber (D) pushes valve spool (3) to the left against spring (4). q Motor port (MB) opens and pressurized oil flows in to revolve the motor in reverse (coun- terclockwise). 18 D155AX-6