SEN00721-01 40 Troubleshooting Failure code [DW7BKA] Fan rev EPC: Disconnection 1 Circuit diagram related to fan reverse solenoid 34 D155AX-6 Action code Failure code F Trouble ( an rev EPC: Disconnection Power train controller system) E01 DW7BKA Contents of trouble • When signal is output to fan reverse solenoid circuit, no current flows. Action of controller • Turns signal to fan reverse solenoid circuit OFF. Problem that appears on machine • Fan reverse function cannot be used. Related information • Operating condition of fan reverse solenoid can be checked with monitoring function. (Code: 40909 T/M Output 1) • Method of reproducing failure code:
Turn starting switch ON + Select fan reverse mode. Possible cause and standard value in norma state Cause a Defective fan reverse sole- 1 noid (Internal disconnection) a Disconnection in wiring har- s ness (Disconnection in wiring W 2 or defective contact in con- – l nector) W – a Hot short (Short circuit with 3 24V circuit) in wiring harness W – If Defective power train con- 4 d troller c Standard value in normal state/Remarks on troubleshooting Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
FAR (male) Resistance Between (1) – (2) 34 – 44 z Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. iring harness between STC3 (female) (18) FAR (female) (1) Resis- M tance ax. 1 z iring harness between STC3 (female) (13) FAR (female) (2) Resis- M tance ax. 1 z Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. iring harness between STC3 (female) (18) FAR (female) (1) and chassis ground Voltage M ax. 1 V causes 1 – 3 are not detected, power train controller may be efective. (Since trouble is in system, troubleshooting cannot be arried out.)