40 Troubleshooting SEN00721-01 Failure code [DWN2KA] Hss EPC2: Disconnection 1 Circuit diagram related to HSS right EPC solenoid D155AX-6 39 Action cod e Failure code Trouble Hss EPC2: Disconnection (Power train controller system) E03 DWN2KA Contents trouble of • When signal is output to HSS right EPC solenoid circuit, no current flows. Action of controlle • Turns signal to HSS right EPC solenoid circuit OFF. r • Limits operation of engine and transmission. Problem th appears o machine at • Once machine is stopped, engine speed is limited to medium (half). n • Once machine is stopped, travel is limited to F1 and R1.
Related informatio • Output to HSS right EPC solenoid can be checked with monitoring function. (Code: 50601 HSS Solenoid RH (F/B)) n • Method of reproducing failure code: Turn starting switch ON + Operate PCCS lever (Right steering).
Possible cau and standa value in nor state Cause Defective HSS right EPC 1 solenoid (Internal disconnec- tion) Disconnection in wiring har- ness (Disconnection in wiring ses 2 or defective contact in con- rd nector) mal Hot short (Short circuit with 3 24V circuit) in wiring harness Defective power train con- 4 troller Standard value in normal state/Remarks on troubleshooting a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. HSR (male) Resistance Between (1) – (2) 4.5 – 14.5 z Resistance 4.5 – 14.5 z a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
Wiring harness between STC3 (female) (35) Resis- Max. 1 z – HSR (female) (1) tance Wiring harness between STC3 (female) (3) Resis- Max. 1 z – HSR (female) (2) tance Resis- tance Max. 1 z Resis- tance Max. 1 z a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between STC3 (female) (3) – HSR (female) (2) or circuit branch end and Voltage Max. 1 V chassis ground Voltage Max. 1 V If causes 1 – 3 are not detected, power train controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)