SEN00721-01 40 Troubleshooting Failure code [DWN2KB] Hss EPC2: Short circuit 1 Circuit diagram related to HSS right EPC solenoid 40 D155AX-6 Action cod e Failure code Trouble Hss EPC2: Short circuit (Power train controller system) E03 DWN2KB Contents trouble of • When signal is output to HSS right EPC solenoid circuit, abnormal current flowed. Action of controller • Turns signal to HSS right EPC solenoid circuit OFF. • Limits operation of engine and transmission. Problem th appears o machine at • Once machine is stopped, engine speed is limited to medium (half). n • Once machine is stopped, travel is limited to F1 and R1.
Related informatio • Output to HSS right EPC solenoid can be checked with monitoring function. (Code: 50601 HSS Solenoid RH (F/B)) n • Method of reproducing failure code: Turn starting switch ON + Operate PCCS lever (Right steering). Possible cau and standa value in nor state Cause Defective HSS right EPC 1 solenoid (Internal short cir- cuit) ses Ground fault in wiring har- rd 2 ness (Contact with GND cir- mal cuit) Short circuit in wiring har- 3 ness (with another wiring harness) Defective power train con- 4 troller Standard value in normal state/Remarks on troubleshooting a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
HSR (male) Resistance Between (1) – (2) 4.5 – 14.5 z Between (1) – chassis ground Min. 1 Mz Resistance 4.5 – 14.5 z Min. 1 Mz a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (35) Resis- Min. 1 Mz – HSR (female) (1) and chassis ground tance Resis- tance Min. 1 Mz a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (35) Resis- – HSR (female) (1) and between STC3 Min. 1 Mz tance (female) (3) – HSR (female) (2) Resis- tance Min. 1 Mz If causes 1 – 3 are not detected, power train controller may be defective.
(Since trouble is in system, troubleshooting cannot be carried out.)