Komatsu D155AX-6 — FAILURE CODE [DWN5KA] FAN PUMP SOLENOID: DISCONNECTION

SEN00721-01 40 Troubleshooting Failure code [DWN5KA] Fan pump solenoid: Disconnection 1 Circuit diagram related to fan control solenoid 48 D155AX-6 Action code Failure code Trouble Fan pump solenoid: Disconnection (Power train controller system) E01 DWN5KA Contents of trouble • When signal is output to fan pump EPC solenoid circuit, no current flows. Action of controller • Turns signal to fan pump EPC solenoid circuit OFF. Problem that appears on machine • Fan speed is kept at maximum. Related information • Output to fan pump EPC solenoid can be checked with monitoring function. (Code: 31624 Fan pump Solenoid (F/B)) • Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective fan pump EPC 1 solenoid (Internal disconnec- tion) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. FAC (male) Resistance Between (1) – (2) 2 – 12 z Disconnection in wiring har- ness (Disconnection in wiring 2 or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (36) – FAC (female) (1) Resis- Ma tance x. 1 z Wiring harness between STC3 (female) (23) – FAC (female) (2) Resis- Ma tance x.

1 z Hot short (Short circuit with 3 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between STC3 (female) (23) – FAC (female) (2) or circuit branch end and chassis ground Voltage Ma x. 1 V Defective power train con- 4 troller If causes 1 – 3 are not detected, power train controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)