40 Troubleshooting SEN00721-01 Failure code [DWN5KB] Fan pump solenoid: Short circuit 1 Circuit diagram related to fan control solenoid D155AX-6 49 Action code Failure code Trouble Fan pump solenoid: Short circuit (Power train controller system) E01 DWN5KB Contents of trouble • When signal was output to fan pump EPC solenoid circuit, abnormal current flowed. Action of controller • Turns signal to fan pump EPC solenoid circuit OFF. Problem that appears on machine • Fan speed is kept at maximum. Related information • Output to fan pump EPC solenoid can be checked with monitoring function. (Code: 31624 Fan pump Solenoid (F/B)) • Method of reproducing failure code: Turn starting switch ON.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective fan pump EPC 1 solenoid (Internal short cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. FAC (male) Resistance Between (1) – (2) 2 – 12 z Between (1) – chassis ground Min. 1 Mz Ground fault in wiring har- 2 ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (36) – FAC (female) (1) and chassis ground Resis- Min.
tance 1 Mz Short circuit in wiring har- 3 ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (36) – FAC (female) (1) and between STC3 (female) (23) – FAC (female) (2) Resis- Min. tance 1 Mz Defective power train con- 4 troller If causes 1 – 3 are not detected, power train controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)