Komatsu D155AX-6 — FAILURE CODE [DXA0KY] TVC SOL.: SHORT CIRCUIT

SEN00721-01 40 Troubleshooting Failure code [DXA0KY] TVC Sol.: Short circuit 1 Circuit diagram related to work equipment-HSS pump TVC solenoid 52 D155AX-6 Action code Failure code Trouble TVC Sol.: Short circuit (Work equipment controller system) E01 DXA0KY Contents of trouble • When signal was output to work equipment-HSS pump TVC solenoid circuit, abnormal current flowed. Action of controller • Turns signal to work equipment-HSS pump TVC solenoid circuit OFF. Problem that appears on machine • Work equipment speed may be lowered. Related information • Output to work equipment-HSS pump TVC solenoid can be checked with monitoring function. (Code:

01300 TVC Solenoid (F/B)) • Method of reproducing failure code: Turn starting switch ON. Possible cause and standard value in norma state Cause Defective work equipment- 1 HSS pump TVC solenoid (Internal disconnection) Hot short (Short circuit with 2 s 24V circuit) in wiring harnes l Short circuit in wiring har- 3 ness (with another wiring harness) Defective work equipment 4 controller Standard value in normal state/Remarks on troubleshooting a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. TVC (male) Resistance Between (1) – (2) 2 – 12 z Between (1) – chassis ground Min. 1 Mz Resistance 2 – 12 z und Min.

1 Mz a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. s Wiring harness between WEC3 (female) (7) Voltage Max. 1 V – TVC (female) (1) and chassis ground Voltage Max. 1 V a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC3 (female) (7) Resis- – TVC (female) (1) and between WEC3 Min. 1 Mz tance (female) (3) – TVC (female) (2) Resis- tance Min. 1 Mz a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (7) – (3) 2 – 12 z Between (7) – chassis ground Min. 1 Mz Resistance 2 – 12 z und Min.

1 Mz