Komatsu D155AX-6 — FAILURE CODE [DXH1KA] LOCK-UP ECMV: DISCONNECTION

SEN00721-01 40 Troubleshooting Failure code [DXH1KA] Lock-up ECMV: Disconnection 1 54 D155AX-6 Action code Failure code Trouble Lock-up ECMV: Disconnection (Power train controller system) E02 DXH1KA Contents of trouble • When signal is output to torque converter lockup clutch ECMV solenoid circuit, no current flows. Action of controller • Turns signal to torque converter lockup clutch ECMV solenoid circuit OFF. Problem that appears on machine • Torque converter lockup function does not operate. Related information • Output to torque converter lockup clutch ECMV solenoid can be checked with monitoring function. (Code: 31642 L/U ECMV (F/B)) • Method of reproducing failure code:

Start engine + Drive forward (in auto gearshift mode). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective lockup clutch ECMV solenoid (Internal dis- connection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. SLUC (male) Resistance Between (1) – (2) 3.5 – 12.5 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (17) – SLUC (female) (1) Resis- tance Max.

1 z Wiring harness between STC3 (female) (13) – SLUC (female) (2) Resis- tance Max. 1 z 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between STC3 (female) (17) – SLUC (female) (1) and chassis ground Voltage Max. 1 V 4 Defective power train con- troller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. STC3 (female) Resistance Between (17) – (13) 3.5 – 12.5 z