SEN00722-01 40 Troubleshooting Failure code [DXH6KY] 3rd clutch ECMV: Short circuit 1 Circuit diagram related to transmission 3rd clutch ECMV 10 D155AX-6 Action code Failure code 3 Trouble ( rd clutch ECMV: Short circuit Power train controller system) E03 DXH6KY Contents of • trouble When signal was output to transmission 3rd clutch ECMV solenoid circuit, abnormal current flowed. Action of • controller • Turns signal to transmission 3rd clutch ECMV solenoid circuit OFF. Limits operation of engine and transmission. Problem that • appears on • machine Once machine is stopped, engine speed is limited to medium (half). Once machine is stopped, travel is limited to F1 and R1.
• Related information • Output to 3rd clutch ECMV solenoid can be checked with monitoring function. (Code: 31604 T/M Clutch 3rd ECMV (F/B)) Method of reproducing failure code: Start engine + Set gear to F3 or R3. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting a Defective 3rd clutch ECMV 1 solenoid (Internal short cir- cuit) Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. S3T (male) Resistance Between (1) – (2) 3.5 – 12.5 z Between (1) – chassis ground Min.
1 Mz a Hot short (Short circuit with 2 24V circuit) in wiring harness W – Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. iring harness between STC3 (female) (26) S3T (female) (1) and chassis ground Voltage M ax. 1 V a Short circuit in wiring har- 3 ness (with another wiring W harness) – (f Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. iring harness between STC3 (female) (26) S3T (female) (1) and between STC3 emale) (23) – S3T (female) (2) Resis- Mi tance n. 1 Mz If Defective power train con- 4 d troller c causes 1 – 3 are not detected, power train controller may be efective.
(Since trouble is in system, troubleshooting cannot be arried out.)