Komatsu D155AX-6 — FAILURE CODE [DXH8KA] F CLUTCH ECMV: DISCONNECTION

SEN00722-01 40 Troubleshooting Failure code [DXH8KA] F clutch ECMV: Disconnection 1 Circuit diagram related to transmission F clutch ECMV 14 D155AX-6 Action code Failure code DXH8KA F Trouble ( clutch ECMV: Disconnection Power train controller system) E03 Contents of trouble • When signal is output to transmission F clutch ECMV solenoid circuit, no current flows. Action of controller • Turns signal to transmission F clutch ECMV solenoid circuit OFF. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to R1.

Related information • Output to F clutch ECMV solenoid can be checked with monitoring function. (Code: 31622 T/M Clutch F ECMV (F/B)) • Method of reproducing failure code: Start engine + Set gear to F (Forward).

Possible cause and standard value in norma state Cause a Defective F clutch ECMV 1 solenoid (Internal disconnec- tion) a Disconnection in wiring har- ness (Disconnection in wiring W s 2 or defective contact in con- – nector) l W – a Hot short (Short circuit with 3 W 24V circuit) in wiring harness – c If Defective power train con- 4 d troller c Standard value in normal state/Remarks on troubleshooting Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. SFT (male) Resistance Between (1) – (2) 3.5 – 12.5 z Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

iring harness between STC3 (female) (27) SFT (female) (1) Resis- tance Max. 1 z iring harness between STC3 (female) (13) SFT (female) (2) Resis- tance Max. 1 z Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. iring harness between STC3 (female) (13) SFT (female) (2) or circuit branch end and hassis ground Voltage Max. 1 V causes 1 – 3 are not detected, power train controller may be efective. (Since trouble is in system, troubleshooting cannot be arried out.)