SEN00722-01 40 Troubleshooting Failure code [DXHRKY] Blade up EPC: Short circuit 1 Circuit diagram related to blade lift-up EPC solenoid 32 D155AX-6 Action cod e Failure code Trouble Blade up EPC: Short circuit (Work equipment controller system) E03 DXHRKY Contents trouble of • When signal was output to blade lift-up EPC solenoid circuit, abnormal current flowed. Action of controlle • Turns signal to blade lift-up EPC solenoid circuit OFF. r • Limits operation of engine and transmission. Problem th appears o machine at • Blade cannot be lifted up. n • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to R1.
Related informatio • Output to blade lift-up EPC solenoid can be checked with monitoring function. (Code: 71001 Blade Raise EPC (F/B)) n • Method of reproducing failure code: Turn starting switch ON + Operate blade control lever (Raise). Possible cau and standa value in nor state Cause Defective blade lift-up EPC 1 solenoid (Internal short cir- cuit) ses rd Hot short (Short circuit with mal 2 24V circuit) in wiring harness Defective work equipment 3 controller Standard value in normal state/Remarks on troubleshooting Defective blade lift-up EPC olenoid (Internal short cir- uit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
WEP1 (male) Resistance Between (1) – (2) 4.5 – 14.5 z Between (1) – chassis ground Min. 1 Mz Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between WEC3 (female) (6) – WEP1 (female) (1) and chassis ground Voltage Ma x. 1 V Defective work equipment ontroller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (6) - (13) 4.5 – 14.5 z Between (6) - chassis ground Min. 1 Mz