Komatsu D155AX-6 — FAILURE CODE [DXHRKB] BLADE UP EPC: SHORT CIRCUIT

40 Troubleshooting SEN00722-01 Failure code [DXHRKB] Blade up EPC: Short circuit 1 Circuit diagram related to blade lift-up EPC solenoid D155AX-6 31 Action cod e Failure code Trouble Blade up EPC: Short circuit (Work equipment controller system) E03 DXHRKB Contents trouble of • When signal was output to blade lift-up EPC solenoid circuit, abnormal current flowed. Action of controlle • Turns signal to blade lift-up EPC solenoid circuit OFF. r • Limits operation of engine and transmission. Problem th appears o machine at • Blade cannot be lifted up. n • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to R1.

Related informatio • Output to blade lift-up EPC solenoid can be checked with monitoring function. (Code: 71001 Blade Raise EPC (F/B)) n • Method of reproducing failure code: Turn starting switch ON + Operate blade control lever (Raise). Possible cau and standa value in nor state Cause Defective blade lift-up EPC 1 solenoid (Internal short cir- cuit) ses rd Ground fault in wiring har- mal 2 ness (Contact with GND cir- cuit) Defective work equipment 3 controller Standard value in normal state/Remarks on troubleshooting Defective blade lift-up EPC olenoid (Internal short cir- uit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

WEP1 (male) Resistance Between (1) – (2) 4.5 – 14.5 z Between (1) – chassis ground Min. 1 Mz Ground fault in wiring har- ness (Contact with GND cir- uit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC3 (female) (6) – WEP1 (female) (1) and chassis ground Resis- Min. tance 1 Mz Defective work equipment ontroller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (6) – (13) 4.5 – 14.5 z Between (6) – chassis ground Min. 1 Mz