40 Troubleshooting SEN00722-01 Failure code [DXHXKA] Ripper down EPC: Disconnection 1 Circuit diagram related to ripper lift-down EPC solenoid D155AX-6 45 Action code Failure code Trouble Ripper down EPC: Disconnection (Work equipment controller system) E03 DXHXKA Contents of • trouble When signal is output to ripper lift-down EPC solenoid circuit, no current flows. Action of • T controller • L urns signal to ripper lift-down EPC solenoid circuit OFF. imits operation of engine and transmission. Problem that • appears on • machine • Ripper cannot be lifted down. Once machine is stopped, engine speed is limited to medium (half). Once machine is stopped, travel is limited to R1.
• Related ( information • Output to ripper lift-down EPC solenoid can be checked with monitoring function. Code: 71103 Ripper Down EPC (F/B)) Method of reproducing failure code: Turn starting switch ON + Operate ripper control lever (Lower). 1 Possible causes and standard value in normal 2 state 3 Cause Standard value in normal state/Remarks on troubleshooting Defective ripper lift-down EPC solenoid (Internal dis- connection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
WEP8 (male) Resistance Between (1) – (2) 2 – 12 z Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC3 (female) (15) – WEP8 (female) (1) Resis- tance Max. 1 z Wiring harness between WEC3 (female) (23) – WEP8 (female) (2) Resis- tance Max. 1 z Defective work equipment controller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (15) – (23) 2 – 12 z