Komatsu D155AX-6 — FAILURE CODE [DXHXKB] RIPPER DOWN EPC: SHORT CIRCUIT

SEN00722-01 40 Troubleshooting Failure code [DXHXKB] Ripper down EPC: Short circuit 1 Circuit diagram related to ripper lift-down EPC solenoid 46 D155AX-6 Action code Failure code Trouble Ripper down EPC: Short circuit (Work equipment controller system) E03 DXHXKB Contents of • trouble When signal was output to ripper lift-down EPC solenoid circuit, abnormal current flowed. Action of • T controller • L urns signal to ripper lift-down EPC solenoid circuit OFF. imits operation of engine and transmission. Problem that • appears on • machine • Ripper cannot be lifted down. Once machine is stopped, engine speed is limited to medium (half). Once machine is stopped, travel is limited to R1.

• Related ( information • Output to ripper lift-down EPC solenoid can be checked with monitoring function. Code: 71103 Ripper Down EPC (F/B)) Method of reproducing failure code: Turn starting switch ON + Operate ripper control lever (Lower). 1 Possible causes and standard value in normal 2 state 3 Cause Standard value in normal state/Remarks on troubleshooting Defective ripper lift-down EPC solenoid (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEP8 (male) Resistance Between (1) – (2) 2 – 12 z Between (1) – chassis ground Min.

1 Mz Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC3 (female) (15) – WEP8 (female) (1) and chassis ground Resis- tance Min. 1 Mz Defective work equipment controller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (15) – (23) 2 – 12 z Between (15) – chassis ground Min. 1 Mz