Komatsu D155AX-6 — FAILURE CODE [DXHZKY] RIPPER TILT BACK EPC: SHORT CIRCUIT

40 Troubleshooting SEN00722-01 Failure code [DXHZKY] Ripper Tilt Back EPC: Short circuit 1 Circuit diagram related to ripper tilt-back EPC solenoid D155AX-6 53 Action code Failure code Trouble Ripper Tilt Back EPC: Short circuit (Work equipment controller system) E03 DXHZKY Contents of trouble • When signal was output to ripper tilt-back EPC solenoid circuit, abnormal current flowed. Action of controller • Turns signal to ripper tilt-back EPC solenoid circuit OFF. • Limits operation of engine and transmission. Problem that appears on machine • Ripper cannot be tilted back. • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to R1.

Related information • Output to ripper tilt-back EPC solenoid can be checked with monitoring function. (Code: 71107 Ripper Tilt Back EPC (F/B)) • Method of reproducing failure code: Turn starting switch ON + Operate ripper control lever (Tilt back). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective ripper tilt-back 1 EPC solenoid (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEPA (male) Resistance Between (1) – (2) 2 – 12 z Between (1) – chassis ground Min.

1 Mz Hot short (Short circuit with 2 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between WEC3 (female) (35) – WEPA (female) (1) and chassis ground Voltage Ma x. 1 V Defective work equipment 3 controller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (35) – (23) 2 – 12 z Between (35) – chassis ground Min. 1 Mz