SEN00722-01 40 Troubleshooting Failure code [DXJ4KA] Weq lock Sol.: Disconnection 1 Circuit diagram related to work equipment lock solenoid 54 D155AX-6 Action code Failure code Trouble Weq lock Sol.: Disconnection (Work equipment controller system) E03 DXJ4KA Contents of • trouble When signal is output to work equipment lock solenoid circuit, no current flows. Action of • controller Turns signal to work equipment lock solenoid circuit OFF. Problem that appears on • machine Blade and ripper cannot be operated. Related • information Method of reproducing failure code: Turn starting switch ON + Operate work equipment lock lever (Free).
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective work equipment 1 lock solenoid (Internal dis- connection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WLK (male) Resistance Between (1) – (2) 20 – 60 z Disconnection in wiring har- ness (Disconnection in wiring 2 or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC3 (female) (8) – WLK (female) (1) Resis- Ma tance x.
1 z Wiring harness between WEC3 (female) (3) – WLK (female) (2) Resis- Ma tance x. 1 z Defective work equipment 3 controller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (8) – (3) 20 – 60 z