40 Troubleshooting SEN00722-01 Failure code [DXJ4KB] Weq lock Sol.: Short circuit 1 Circuit diagram related to work equipment lock solenoid D155AX-6 55 Action code Failure code Trouble Weq lock Sol.: Short circuit (Work equipment controller system) E03 DXJ4KB Contents of • trouble When signal was output to work equipment lock solenoid circuit, abnormal current flowed. Action of • controller Turns signal to work equipment lock solenoid circuit OFF. Problem that appears on • machine Blade and ripper cannot be operated. Related • information Method of reproducing failure code: Turn starting switch ON + Operate work equipment lock lever (Free).
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective work equipment 1 lock solenoid (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WLK (male) Resistance Between (1) – (2) 20 – 60 z Between (1) – chassis ground Min. 1 Mz Ground fault in wiring har- 2 ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC3 (female) (8) – WLK (female) (1) and chassis ground Resis- Min.
tance 1 Mz Hot short (Short circuit with 3 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between WEC3 (female) (8) – WLK (female) (1) and chassis ground Voltage Ma x. 1 V Defective work equipment 4 controller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (8) – (3) 20 – 60 z Between (8) – chassis ground Min. 1 Mz