SEN00723-01 40 Troubleshooting Failure code [DXJAKA] Q-drop EPC: Disconnection 1 8 D155AX-6 Action code Failure code Trouble Q-drop EPC: Disconnection (Work equipment controller system) E01 DXJAKA Contents of trouble • When signal is output to blade quick drop EPC solenoid circuit, no current flows. Action of controller • Turns signal to blade quick drop EPC solenoid circuit OFF. Problem that appears on machine • Blade quick drop function does not operate. Related information • Output to blade quick drop EPC solenoid can be checked with monitoring function. (Code: 90900 Quick Drop Solenoid (F/B)) • Method of reproducing failure code:
Turn starting switch ON + Operate blade control lever (Lower). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective blade quick drop EPC solenoid (Internal dis- connection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. QDP (male) Resistance Between (1) – (2) 4.5 – 14.5 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC3 (female) (37) – QDP (female) (1) Resis- tance Max.
1 z Wiring harness between WEC3 (female) (3) – QDP (female) (2) Resis- tance Max. 1 z 3 Defective work equipment controller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (37) – (3) 4.5 – 14.5 z