Komatsu D155AX-6 — E-4 PREHEATER DOES NOT OPERATE

40 Troubleshooting SEN00807-01 D155AX-6 15 Trouble (2) When starting switch is turned to HEAT position, intake air heater mounting part does not become warm. Related information • Check that engine can be turned with starting motor (If engine cannot be turned, carry out trouble- shooting for E-3 Engine does not start (Engine does not turn)). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective circuit breaker (CB105H) If circuit breaker is turned OFF, circuit probably has ground fault (See cause 5).

2 Defective heater relay (Inter- nal disconnection) a Prepare with starting switch OFF (with wiring harness con- nected), then turn starting switch to HEAT and carry out trou- bleshooting. Heater relay Starting switch Voltage Between HT – chassis ground HEAT 20 – 30 V Between HT/B – chassis ground 20 – 30 V 3 Defective intake air heater (Internal disconnection) a Prepare with starting switch OFF (with wiring harness con- nected), then turn starting switch to HEAT and carry out trou- bleshooting in each case. RH1 Starting switc Voltage Between terminal – chassis ground HEAT 20 – 30 V If voltage is normal but heater mounting part does not become warm, intake air heater is defective.

4 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between terminal 255 – ter- minal HT Resis- tance Max. 1 z Wiring harness between terminal BRC – CB105H (B105HS) Resis- tance Max. 1 z Wiring harness between CB105H (B105HL) – terminal HT/A Resis- tance Max. 1 z Wiring harness between terminal HT/B – terminal RHT Resis- tance Max. 1 z 5 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

Wiring harness between terminal 255 – ter- minal HT or CM01 (female) (16) or circuit branch end and chassis ground Resis- tance Min. 1 Mz Wiring harness between terminal BRC – CB105H (B105HS) and chassis ground Resis- tance Min. 1 Mz Wiring harness between CB105H (B105HL) – terminal HT/A and chassis ground Resis- tance Min. 1 Mz Wiring harness between terminal HT/B – terminal RHT and chassis ground Resis- tance Min. 1 Mz