SEN00807-01 40 Troubleshooting 34 D155AX-6 Trouble (3) Air does not come out (Air flow is insufficient). Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective blower relay (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON (coil side). AC03 (male) Resistance Between (1) – (3) 140 – 340 z a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting (contact side).
AC03 Air conditioner switch Voltage Between (4) – chassis ground Air blow position 20 – 30 V 2 Defective power transistor (Internal defect) a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Fan switch If air flow changes according to operation of fan switch, power transistor (PTR) is normal. Operate between Low and Medium and High. 3 Defective blower motor (Internal defect) a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
MB (wiring side) Air conditioner switch Voltage Between (1) – (2) Air blow position 20 – 30 V If above voltage is normal and blower motor does not revolve, blower motor (MB) is defective. 4 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between CB3 (2) – fuse in unit - AC03 (female) (1) Resis- tance Max. 1 z Wiring harness between AC03 (female) (3) – ACW (wiring side) (36) Resis- tance Max. 1 z Wiring harness between CB3 (2) – AC03 (female) (4) Resis- tance Max.
1 z Wiring harness between AC03 (female) (5) – MB (wiring side) (1) Resis- tance Max. 1 z Wiring harness between MB (wiring side) (2) – PTR (wiring side) (3) Resis- tance Max. 1 z Wiring harness between PTR (wiring side) (1) – chassis ground (GND12) Resis- tance Max. 1 z Wiring harness between PTR (wiring side) (2) – ACW (wiring side) (8) Resis- tance Max. 1 z Wiring harness between PTR (wiring side) (4) – ACW (wiring side) (7) Resis- tance Max. 1 z