Komatsu D155AX-6 — E-20 AIR CONDITIONER DOES NOT OPERATE NORMALLY (INCLUDING AIR CONDITIONER FAULT HISTORY)

40 Troubleshooting SEN00807-01 D155AX-6 35 Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 5 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between AC03 (female) (3) – ACW (wiring side) (36) and chassis ground Resis- tance Min. 1 Mz Wiring harness between AC03 (female) (5) – MB (wiring side) (1) and chassis ground Resis- tance Min. 1 Mz Wiring harness between MB (wiring side) (2) – PTR (wiring side) (3) and chassis ground Resis- tance Min.

1 Mz Wiring harness between PTR (wiring side) (2) – ACW (wiring side) (8) and chassis ground Resis- tance Min. 1 Mz 6 Defective air conditioner con- troller If causes 1 – 5 are not detected, air conditioner controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) 7 Defective air conditioner sys- tem If causes 1 – 5 are not detected, air conditioner system may be defective. See Machine Component Volume, Shop Manual, Trou- bleshooting, Air conditioner, Troubleshooting.