Komatsu D155AX-6 — E-20 AIR CONDITIONER DOES NOT OPERATE NORMALLY (INCLUDING AIR CONDITIONER FAULT HISTORY)

SEN00807-01 40 Troubleshooting 36 D155AX-6 Trouble (4) Air is not cooled (Cooling performance is insufficient). Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective compressor relay (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON (coil side). AC04 (male) Resistance Between (1) – (3) 140 – 340 z a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting (contact side).

AC04 Air conditioner switch Voltage Between (2) – chassis ground Cooling position 20 – 30 V 2 Defective internal air sensor Internal air sensor may be defective. Carry out troubleshooting for "Abnormality in internal air sensor". 3 Defective high and low pres- sure switches High and low pressure switches may be defective. Carry out trou- bleshooting for "Abnormality in refrigerant". 4 Defective compressor clutch (Internal defect) Compressor clutch may be defective. Check it directly. 5 Defective compressor (Inter- nal defect) Compressor may be defective. Check it directly.

6 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between CB3 (2) – fuse in unit – AC04 (female) (1) Resis- tance Max. 1 z Wiring harness between AC04 (female) (3) – ACW (wiring side) (35) Resis- tance Max. 1 z Wiring harness between CB3 (2) – AC04 (female) (4) Resis- tance Max. 1 z Wiring harness between AC04 (female) (2) – A/C (female) (1) Resis- tance Max.

1 z 7 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between AC04 (female) (3) – ACW (wiring side) (35) and chassis ground Resis- tance Min. 1 Mz Wiring harness between AC04 (female) (2) – A/C (female) (1) and chassis ground Resis- tance Min. 1 Mz 8 Defective air conditioner con- troller If causes 1 – 7 are not detected, air conditioner controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) 9 Defective air conditioner sys- tem If causes 1 – 7 are not detected, air conditioner system may be defective.

See Machine Component Volume, Shop Manual, Trou- bleshooting, "Air conditioner", Troubleshooting.