40 Troubleshooting SEN00807-01 D155AX-6 37 Trouble (5) Air conditioner fault history: Communication condition "CAN disconnection", Communication condi- tion "Abnormal" Related information • While abnormality in communication is being detected, "CAN disconnection" is displayed. • If abnormality in communication has been detected and reset, "Abnormality" is displayed. • If "CAN disconnection" is displayed as communication condition, communication cannot be carried out normally. Accordingly, condition of other items is not displayed. • Method of reproducing fault history: Turn starting switch ON.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between AC02 (female) (1) – CM02 (female) (8), (9) Resis- tance Max. 1 z Wiring harness between AC02 (female) (2) – CM02 (female) (10) Resis- tance Max. 1 z 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
Wiring harness between AC02 (female) (1) – CM02 (female) (8), (9), EGC2 (female) (46), STC2 (female) (32), WEC2 (female) (32), CA1 (female) (A), or SRV (female) (3) and chassis ground Resis- tance Max. 1 z Wiring harness between AC02 (female) (2) – CM02 (female) (10), EGC2 (female) (47), STC2 (female) (22), WEC2 (female) (22), CA1 (female) (B), or SRV (female) (10) and chassis ground Resis- tance Max. 1 z 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
Wiring harness between AC02 (female) (1) – CM02 (female) (8), (9), EGC2 (female) (46), STC2 (female) (32), WEC2 (female) (32), CA1 (female) (A), or SRV (female) (3) and chassis ground Resis- tance Min. 1 Mz Wiring harness between AC02 (female) (2) – CM02 (female) (10), EGC2 (female) (47), STC2 (female) (22), WEC2 (female) (22), CA1 (female) (B), or SRV (female) (10) and chassis ground Resis- tance Min. 1 Mz 4 Defective CAN terminal resistance (Internal short cir- cuit or disconnection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. CA1 (male) Resistance Between (A) – (B) Approx.
120 z 5 Defective air conditioner con- troller If causes 1 – 4 are not detected, air conditioner controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) 6 Defective machine monitor If causes 1 – 4 are not detected, machine monitor may be defec- tive. (Since trouble is in system, troubleshooting cannot be carried out.)