Komatsu D155AX-6 — E-20 AIR CONDITIONER DOES NOT OPERATE NORMALLY (INCLUDING AIR CONDITIONER FAULT HISTORY)

SEN00807-01 40 Troubleshooting 38 D155AX-6 Trouble (6) Air conditioner fault history: Setting condition "Abnormality" Related information • If setting of air conditioner controller model is different from setting of machine monitor model, "Abnormality" is displayed. • If "CAN disconnection" is displayed as communication condition, communication cannot be carried out normally. Accordingly, this condition is not displayed. • Method of reproducing fault history: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective air conditioner con- troller Air conditioner controller may be defective.

(Since trouble is in system, troubleshooting cannot be carried out.) 2 Defective machine monitor Machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) Trouble (7) Air conditioner fault history: Internal air sensor "Abnormality" Related information • If "CAN disconnection" is displayed as communication condition, communication cannot be carried out normally. Accordingly, this condition is not displayed. • Method of reproducing fault history: Turn starting switch ON + Turn air conditioner (A/C) switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective internal air sensor (Internal disconnection or short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. THI (device side) Resistance Between (1) – (2) 300 z – 430 kz 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between ACW (wiring side) (11) – THI (wiring side) (2) Resis- tance Max.

1 z Wiring harness between ACW (wiring side) (27) – THI (wiring side) (1) Resis- tance Max. 1 z 3 Short circuit in wiring har- ness (with GND circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between ACW (wiring side) (11) – THI (wiring side) (2) and chassis ground Resis- tance Min. 1 Mz 4 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between ACW (wiring side) (11) – THI (wiring side) (2) and chassis ground Voltage Max.

1 V 5 Defective air conditioner con- troller If causes 1 – 4 are not detected, air conditioner controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)