3. If the “ ” and “ ” parts of temperature setting switch (3) are kept pressed at the same time for at least 3 seconds, the troubleshooting mode is displayed on the liquid crystal display.
Monitor Display And Failure Mode l OPERATION Display Failure mode E-- No failure E11 Open in recirculated air sensor E12 Short circuit in recirculated air sensor E15 Open in fresh air sensor E16 Short circuit in coolant temperature sensor E18 Short circuit in sunlight sensor E43 Abnormality in vent damper E44 Abnormality in air mix damper E45 Abnormality in FRESH/RECIRC air damper When more than one failure is detected, press the “ ” portion of temperature setting switch (3) to display the failures in turn. After completing the troubleshooting, press OFF switch (1) again to return to the normal display.
If any abnormality is detected by the self-diagnostic function, ask your KOMATSU distributor to carry out inspection and repair. TEMPERATURE DISPLAY FUNCTION It is possible to switch the set temperature display between °F and °C. If the “ ” and “ ” portions of temperature setting switch (3) are pressed at the same time for more than 5 seconds while the fan is running, the temperature display will switch between °F and °C. (Note that the unit is not displayed.) 2-64 PC300LC/HD-7E0 Degrees Liquid crystal display range °C 18 to 32 °F 63 to 91