Komatsu — CHECK AFTER SHUTING OFF ENGINE

OPERATION -B mode For breaker operations STOPPING THE ENGINE If the engine is abruptly stopped before it has cooled down, engine life may be greatly shortened. Consequently, do not abruptly stop the engine apart from an emer- gency. In particular, if the engine has overheated, do not abruptly stop it but run it at medium speed to allow it to cool gradually, then stop it. 1. Run the engine at low idling speed for about 5 minutes to allow it to gradually cool down. 2. Turn the key in ignition switch (1) to the OFF position and stop the engine. 3. Remove the key from ignition switch (1). CHECK AFTER SHUTING OFF ENGINE 1.

Walk around the machine and check the work equipment, machine exterior, and undercarriage, and check for leakage of oil or water. If any abnormalities are found, repair them. 2. Fill the fuel tank. 3. Check the engine compartment for paper and debris. Clean out any paper and debris to avoid a fire hazard. 4. Remove any mud affixed to the undercarriage. Remark After stopping the engine, if the ignition switch is turned to the ON or START position within approximately 10 seconds, to start the engine again, the monitor display is not reset. The previous screen (before the ignition switch was turned OFF) is displayed. 2-96 PC300LC/HD-7E0