Komatsu — RECOMMENDED FUEL, COOLANT, AND LUBRICANT

MAINTENANCE RECOMMENDED FUEL, COOLANT, AND LUBRICANT Komatsu genuine oils are adjusted to maintain the reliability and durability of Komatsu construction equipment and com- ponents. In order to keep your machine in the best conditioner for long periods of time, it is essential to follow the instructions in this Operation and Maintenance Manual. Failure to follow these recommendations may result in shortened life or excess wear of the engine, power train, cooling system, and/or other components. Commercially available lubricant additives may be good for the machine, but they may also cause harm. Komatsu does not recommend any commercially available lubricant additive.

Use the oil recommended according to the ambient temperature in the chart below. Specified capacity means the total amount of oil including the oil in the tank and the piping. Refill capacity means the amount of oil needed to refill the system during inspection and maintenance. When starting the engine in ambient temperatures below 0°C (50°F), do not use SAE30, even if the daytime temperature rises to 10°C (32°F). Always use multigrade oil such as the recommended SAE10W30 or SAE15W40. If the machine is operated at a temperature below -20°C (-4°F), a separate device is needed, so consult your Komatsu dis- tributor.

When the fuel sulfur content is less than 0.5%, change the engine oil according to the period inspection table given in this Operation and Maintenance Manual. If the fuel sulfur content is more than 0.5%, change the oil according to the following table. Fuel sulfur content Engine oil change interval Above 1.0% 1/4 of regular interval 0.5 to 1.0% 1/2 of regular interval 3-10 PC300LC/HD-7E0