MAINTENANCE To maintain the anticorrosion properties of Supercoolant (AF-NAC), always keep the density of Supercoolant between 30% and 68%. When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mixing table given below. It is actually better to estimate and temperature about 10 o C (18 o F) lower when deciding the mixing ratio. The mixing ratio depends on the ambient temperature, but it should always be a minimum of 30% by volume (antifreeze/total amount of coolant x 100). The freezing temperature of undiluted antifreeze is -15 o C (5 o F). Do not store undiluted antifreeze at a temperature of below - 15 o C (5 o F).
Mixing Rate Of Water And Antifreeze Antifreeze is toxic. When removing the drain plug, be careful not to get coolant containing antifreeze on you. If it gets in your eyes, flush your eyes with large quantities of fresh water and see a doctor at once. We recommend use of an antifreeze density gauge to control the mixing proportions. Prepare a container whose capacity is larger than the specified coolant volume to catch drained coolant. Prepare a hose to supply antifreeze coolant and water. 1. Stop the engine and turn valve (1) of the corrosion resistor fully to the right to close it. (Only machines equipped with corrosion resistor) 3-26 PC300LC/HD-7E0 Min.
ambient temperature °C -10 -15 -20 -25 -30 -35 -40 °F 14 5 -4 -13 -22 -31 -40 Amount of antifreeze liters 9.6 11.5 13.1 14.7 16.0 17.3 18.6 US gal 2.54 3.04 3.46 3.88 4.23 4.57 4.91 Amount of distilled water liters 22.4 20.5 18.9 17.3 16.0 14.7 13.4 US gal 5.92 5.42 4.99 4.57 4.23 3.88 3.54 Volume ratio (%) 30 36 41 46 50 54 58