Komatsu — CHECKING FUNCTION OF ACCUMULATOR

MAINTENANCE CHECKING FUNCTION OF ACCUMULATOR When carrying out the inspection, check first that there is no person or obstacle in the surrounding area. Check the nitrogen gas charge pressure as follows. 1. Stop the machine on firm, level ground. 2. Hold the work equipment in the maximum reach posture (arm fully out, bucket fully dumped) at a height (A) 1.5 m (4 ft 11 in) from the ground. Carry out Steps 3 - 5 within 15 seconds. When the engine is stopped, the pressure in the accumulator gradually goes down. For this reason, the check can only be carried out immediately after the engine is stopped. 3.

Keep the work equipment at the maximum reach, turn the ignition switch to the OFF position (A), and stop the engine. 4. Turn the ignition switch to the ON position (B). 5. With the lock lever at the FREE position (F), operate the work equipment control levers fully in the LOWER direction and check to be sure the work equipment is lowered to the ground. PC300LC/HD-7E0 3-71