Komatsu — RELEASING PRESSURE IN HYDRAULIC CIRCUIT

MAINTENANCE 6. If the work equipment goes down under its weight and contacts the ground, the accumulator is normal. If the work equipment does not go down or stops in midway, the charged pressure of the gas in the accumulator for the hydraulic circuit has probably dropped. Contact your Komatsu distributor for inspection. 7. This completes the inspection. After completion of the inspection, set the lock lever to the LOCK position and turn the ignition switch to the OFF position. RELEASING PRESSURE IN HYDRAULIC CIRCUIT 1. Place the work equipment on the ground. Close the crusher attachment jaws, etc. 2. Operate the work equipment lock lever to the LOCK position. 3.

Insert the lock pin for the attachment control pedal in position (c) where it is possible to operate the pedal. (If equipped) Carry out Steps 4 - 6 within 15 seconds. When the engine is stopped, the pressure in the accumulator gradually goes down. For this reason, the check can only be carried out immedi- ately after the engine is stopped. 4. Stop the engine. 5. Turn the ignition switch to the ON position (B). 6. Set lock lever to FREE position (F), then operate the work equipment control levers and the attachment control pedal (if equipped) fully to the front, rear, left, and right to release the pressure in the control circuit. 3-72 PC300LC/HD-7E0