OPTIONS, ATTACHMENTS HYDRAULIC CIRCUIT When a breaker is installed, it is necessary to connect the return circuit directly to the return filter, so use only B mode. Do not use any other mode. The standard set pressure of the service valve safety valve depends on the mode selected when the machine is shipped from the factory. If B mode is selected: 175 kgf/cm 2 (2490 psi) If P or E mode is selected: 205 kgf/cm 2 (2910 psi) Adjustment may be needed depending on the attachment, please contact your Komatsu distributor. SWITCHING THE HYDRAULIC CIRCUIT Depending on the type of attachment, set the working mode on the monitor as follows.
The set pressure of the service valve, safety valve and the hydraulic circuit switch is according to the working mode selected. ADJUSTING OIL FLOW Depending on the attachment, it is necessary to change the oil flow in the service circuit. For details of setting the oil flow, see “BLEEDING AIR FROM HYDRAULIC SYSTEM” on page 3-42. SWITCHING BETWEEN BREAKER AND GENERAL ATTACHMENT 1. When an attachment is installed and B mode is selected: A. The circuit becomes a circuit for breaker operation (1-way circuit). B. The hydraulic oil flowing in the breaker circuit flows to the additional filter for the breaker. C. The relief valve is set to a lower pressure. When shipped from factory:
175 kgf/cm 2 (2490 psi) D. It is possible to adjust the maximum flow with the select mode. 2. When an attachment is installed and P mode or E mode is selected: A. The circuit becomes a circuit for crusher operation (2-way circuit). B. The hydraulic oil flowing in the crusher circuit does not flow to the additional filter for the breaker. C. The relief valve is set to a higher pressure. When shipped from factory: 205 kgf/cm 2 (2910 psi) D. It is possible to adjust the maximum flow with the select mode.
PC300LC/HD-7E0 5-9 Attachment Working mode Hydraulic circuit Set pressure of service safety valve Breaker or other attachment with one-way circuit B mode Return circuit automatically switched so that it does not pass through control valve When shipped from factory : 175 kgf/cm2 (2490 psi) Crusher or other attachment with two-way circuit P mode or E mode Return circuit automatically switched so that it passes through control valve When shipped from factory : 205 kgf/cm2 (2910 psi)