OPTIONS, ATTACHMENTS HYDRAULIC CIRCUIT CONNECTION When connecting the attachment, connect the hydraulic circuit as follows. 1. Remove blind plugs (1) at the end of the stop valve piping (two spots on the left and right). Be careful not to lose or damage any parts that have been removed. 2. Connect attachment piping (2) provided by the attachment maker to the part from which the plug was removed Step 1. For the mouthpiece size and accumulator add-on, the action to take differs according to the attachment manufacturer, consult your Komatsu distributor. 5-10 PC300LC/HD-7E0