EPA07 MBE 4000 OPERATOR'S MANUAL Battery Explosion and Acid Burn To avoid injury from battery explosion or contact with battery acid, work in a well ventilated area, wear protective clothing, and avoid sparks or flames near the battery. If you come in contact with battery acid: Table 1 Approved Electrical Lubricants Flush your skin with water. Apply baking soda or lime to help neutralize the acid. Flush your eyes with water. Get medical attention immediately. Make sure cable connections to the storage batteries are clean and tight. Check the hydrometer “eye” of maintenance-free batteries for charge. See Figure 12.
Figure 12 Maintenance-Free Battery If lead-acid or low-maintenance batteries are used, make sure battery electrolyte level is normal. Check the turbocharger for signs of oil or exhaust leaks. Leaks should be corrected before starting the engine. Check engine mounting bolts for tightness. Bolts should be retightened, if necessary. Use only batteries that have been correctly filled and serviced. To provide corrosion protection, apply dielectric grease liberally to the terminal pads. Approved suppliers are Listed in Table 1. All information subject to change without notice. 23 DDC-SVC-MAN-0041 Copyright © 2009 DETROIT DIESEL CORPORATION Manufacturer Lubricant or Part Number Shell Oil Co. No.
71032; No. 71306 Texaco, Inc. No. 955 Quaker State No. NYK-77