EPA07 MBE 4000 OPERATOR'S MANUAL corrected. Authorized Detroit Diesel service outlets are properly equipped to perform this service. NOTICE: Stopping a turbocharged engine immediately after high-speed operation without allowing a sufficient cool-down period may cause damage to the turbocharger, as it will continue to turn without an oil supply to the bearings. Avoid Unnecessary Idling Whenever possible, avoid unnecessary idling. Never allow the engine to idle for more than 30 minutes. Excessive idling can cause oil to leak from the turbocharger. 2. Allow the engine to run between idle and 1000 rpm with no load for four or five minutes.
This allows the engine to cool and permits the turbocharger to slow down. After four or five minutes, shut down the engine. During long engine idling periods with the transmission in neutral, the engine coolant temperature may fall below the normal operating range. The incomplete combustion of fuel in a cold engine will cause crankcase oil dilution, formation of lacquer or gummy deposits on the valves, pistons, and rings, and rapid accumulation of sludge in the engine. When prolonged idling is necessary, maintain at least 850 rpm spring/summer and 1200 rpm fall/winter. Emergency Jump Starting The DDEC VI system operates on 12 volts DC.
If a DDEC VI engine with an electric starting motor requires emergency jump starting, do not exceed 16 volts DC. Stopping the Engine Stop an engine under normal operating conditions as follows: 1. Reduce engine speed to idle and put all shift levers in the neutral position. All information subject to change without notice. 27 DDC-SVC-MAN-0041 Copyright © 2009 DETROIT DIESEL CORPORATION