MAN — Man EPA07 MBE 4000 Engine Operator's Manual

EPA07 MBE 4000 OPERATOR'S MANUAL Preventive Maintenance Intervals This section describes the items listed in the tables. As the operator of a vehicle, routine “Daily” inspections of the engine and chassis should be performed. This will provide the best opportunity to identify major concerns or concerns that could stretch a longer time span like slow coolant loss. Figure 25 Oil Dipstick For new or stored engines, refer to section “OPERATING INSTRUCTIONS FOR STARTING THE ENGINE” in this guide. NOTICE: When adding lubricating oil, do not overfill. Oil may be blown out through the crankcase breather and/or aeration of the oil can occur. Item 1 – Lubricating Oil Filter Lubricating Oil:

Check the oil level daily with the engine stopped. If the engine has just been stopped and is warm, wait approximately 20 minutes to allow the oil to drain back into the oil pan before checking. Add the proper grade of oil to maintain the correct level on the dipstick. See Figure 25. All diesel engines are designed to use some oil, so the periodic addition of oil is normal. NOTICE: If the oil level is constantly above normal and excess oil has not been added to the crankcase, consult with an authorized Detroit Diesel service outlet for the cause. Fuel or coolant dilution of lubricating oil can result in serious engine damage.

Before adding lubricating oil, refer to section “How to Select Lubricating Oil” in this guide. All information subject to change without notice. 73 DDC-SVC-MAN-0041 Copyright © 2009 DETROIT DIESEL CORPORATION