CLAAS ARGO K50, K60, K70 — SECTION 2 ELECTRICS

2.40 ELECTRICS ALTERNATOR The alternator is capable of producing the total electrical power requirements of the machine. It is fitted on the inboard side of the engine and belt driven from the crankshaft pulley. The alternator contains an integral voltage regulator. The following precautions must be taken to avoid damage to the alternator and voltage regulator: 1 Do not disconnect the battery while the engine is running. This will cause a voltage surge in the alternator charge system which will damage the diodes and/or transistors. 2 Do not short any connections to ground. 3 Do not check the current flow using “spark contact”.

4 Always disconnect the battery ground terminal before removing the alternator. 5 Always disconnect the battery ground terminal when charging the battery in the vehicle using a battery charger. Alternator drive belt check To ensure maximum life from the drive belt it is recommended that the drive belt be checked at regular intervals, as detailed in the Operator’s Manual, for wear, damage and tension. Visually check the belt for signs of wear or damage and replace as necessary. 1. Check the belt tension as follows.(For best results a ‘Fenner’ or similar belt tension gauge should be used). 2.

Fit the gauge at the centre of the longest free length and check the tension in accordance with the manufactures instructions. 3. If no gauge is available, press the belt with the thumb at the centre of the longest free length using a force of 45 N. The resultant belt deflection should be 10 mm. 4. If the belt tension has to be adjusted carry out the following steps: 5. Loosen the pivot fasteners of the alternator (1) and the adjustment bar (2). Adjust the alternator to give the correct tension and tighten the fasteners. 6. Recheck the belt tension.