Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — DISASSEMBLY AND ASSEMBLY OF CONTROL VALVE ASSEMBLY

SEN00951-00 50 Disassembly and assembly Disassembly and assembly of control valve assembly 1 a In this section, only precautions for assembly of the control valve assembly are explained. a For details and tightening torque of each part, see Structure, function and maintenance standard, Hydraulic system - Control valve. Assembly a Tighten sleeve (2) so that dimension (a) will be in the standard range and punch (b) at the end of sleeve (2) will be directed straight up, and then tighten check valve (1). a After tightening the plug, leave it for at least 2 hours. 3 Plug: 9.8 ± 2.9 Nm {1 ± 0.3 kgm} q Dimension (a): 19 ± 0.75 mm 3 Check valve:

58.8 – 78.5 Nm {6 – 8 kgm} a When tightening plug (3), thoroughly degrease and dry the female threads of the spool and apply a drop (about 0.02 g) of LOCTITE (No. 262) each to 2 places. 4 D65EX, PX, WX-15E0