Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — REMOVAL AND INSTALLATION OF FLOOR FRAME ASSEMBLY

50 Disassembly and assembly SEN00953-00 Removal and installation of floor frame assembly 1 4. Remove cover (1). Special tools 5. Disconnect accumulator hose (2). Removal k Lower the work equipment to the ground safely. Referring to Testing and adjusting, “Releasing residual pressure from work equipment cylinder”, release the residual pressure from the piping. k Disconnect the cable from the negative (–) terminal of the battery. k Collect the air conditioner refrigerant (R134a). k If refrigerant (R134a) gets in your eyes, you may lose your sight.

Accordingly, you must be qualified for handling the refrigerant and put on protective goggles while you are collecting the refrigerant or charging the air conditioner with refrigerant. Collecting and filling work must be con- ducted by a qualified person. 6. Disconnect PPC hoses (3), (4) and (5) from the control valve assembly. q (3): Without color band q (4): Color band of Brown and Green q (5): Color band of Blue 1. Remove the engine hood assembly. For details, see “Removal and installation of engine hood assembly”. 2. Remove the operator's cab assembly. For details, see “Removal and installation of opera- tor's cab assembly”. 3. Remove operator's seat assembly.

D65EX, PX, WX-15E0 17 Symbol Part No. Part name Necessity Q’ty New/remodel Sketch X2 799-703-1200 Service tool kit t 1 799-703-1100 Vacuum pump (100 V) t 1 799-703-1110 Vacuum pump (220 V) t 1 799-703-1120 Vacuum pump (240 V) t 1 799-703-1401 Gas leak detector t 1