Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — HSS PUMP

SEN00285-01 10 Structure, function and maintenance standard Function 1. LS valve q LS valve detects the load and controls the dis- charge amount. q This valve controls main pump delivery (Q) according to differential pressure ( d PLS) [= PP – PLS], called the LS differential pressure (the difference between main pump pressure (PP) and control valve outlet port pressure (PLS)). q Main pump pressure (PP), pressure (PLS) [called LS pressure] coming from the control valve output enter this valve.

q The relationship between the differential pres- sure ( d PLS) [ = PP – PLS], the difference between main pump pressure (PP) and LS pressure (PLS), and discharge amount (Q) changes as shown in the diagram. q During the high load operation, or when the engine speed slowed down etc., the current is supplied to TVC solenoid by the controller command. q It reduces the pump discharge amount (pump absorption torque), and reduces the load of engine. 3. Variable throttle valve q Because the main pump controls its own pres- sure, there is a tendency for the response speed of the swash plate to be quick at high pressure and slow at low pressure.

q The variable throttle valve has been installed for the following reasons. 1) To reduce the swash plate speed between minimum and maximum at high pressure; to reduce the impact force on the rod and other parts of the main pump; and to pre- vent excessive response. 2) To prevent cavitation at the suction port caused by the sudden increase in the suc- tion volume when changing from minimum to maximum. q When the pump discharge pressure (PP) is high, the TVC valve controls the pump so that no more oil than the constant flow (in accor- dance with the discharge pressure) flows even if the stroke of the control valve becomes larger.

It carries out equal horsepower control so that the horsepower absorbed by the pump does not exceed the engine horsepower. 2. TVC valve q The characteristics of the variable throttle valve are as shown in the diagram. It has the function and property of maintaining the response during operations at low pressure by making the area of the opening smaller at high pressure and the area of the opening larger at low pressure, and by preventing the above problems 1) and 2) at high pressure.

q If the load during the operation becomes larger and the pump discharge pressure rises, it reduces the discharge amount from the pump; and if the pump discharge pressure drops, it increases the discharge amount from the pump. q The relationship between pump discharge pres- sure (PP) and pump discharge amount (Q) with the electric current value given to TVC solenoid as the parameter is shown in the diagram. 18 D65EX, PX, WX-15E0