Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — HSS PUMP

10 Structure, function and maintenance standard SEN00285-01 Operation 1. LS valve (1) When control valve is at “neutral” position q LS valve is a 3-way selector valve, with pres- sure [LS pressure] (PLS) from the outlet port of the control valve brought to spring chamber (i), and main pump discharge pressure (PP) brought to chamber (j) of plug (6). q Pump pressure (PP) enters the large diameter end of the piston from port (h). The same pump pressure (PP) also enters the small diameter end of the piston, so the swash plate is moved to the minimum angle by the differ- ence in area of piston (1).

q The size of LS pressure (PLS) + force (F) of spring (3) and the main pump pressure [self pressure] (PP) determines the position of spool (4). q Before the engine is started, servo piston (1) is pushed to the right by spring (7) installed to rod (2). [See right figure: section (A – A)] q If the control lever is at the neutral position when the engine is started, LS pressure (PLS) will be set to 0 MPa {0 kg/cm 2 }. (It is intercon- nected to the drain circuit via the control valve spool) q Spool (4) is pushed to the left, and port (d) and port (c) are connected. D65EX, PX, WX-15E0 19